- Contact Person : Mr. Li Jianpeng
- Company Name : Zhaoyuan Dongpeng Automated Instrument Co., Ltd.
- Tel : 86-535-8139110
- Fax : 86-535-8139121
- Address : Shandong,yantai,No.9 jinduyuan Entrepreneurial Base
- Country/Region : China
UHZ series( Upper and Lower Limit Switch )Magnetic Level Gauge
Magnetic Level Gauge
Range:500~5000mm
Temperature:-40~420 C
Pressure:0~32MPa
Accuracy: 10mm
Medium Density:0.5-2.0g/m3
Medium Density Difference:≥150kg/cm3
Ambient Vibration: Frequency≤25Hz,Amplitude≤0.5mm
Follow speed≤0.08m/s
Medium Viscosity:≤0.4Pa.S
Process Connection: Side-Mounted Flange:DN25,PN1.0 or 1.6,PN2.5
Flange Standard:HG20592~20635-97 other ordered by customer
Material of Wetted Parts: 1Cr18Ni9Ti, 304,316,316L
summarization
UHZ series Magnetic Level Gauge take float as measuring element. Magnetic steel drives column display, not requiring energy. UHZ is suitable for varies environment from Low to high temperature, from vacuum to high pressure, which is ideal level measuring instrument for Petrochemical Industry and etc.
We provide Side-Mounted and Top-Mounted according to installation site in the container.
We provide stainless steel, PP plastic, stainless steel lining teflon etc. according to medium. PP plastic and stainless steel lining teflon are ideal for acid and alkali corrosive medium.
Structure Characteristic
Basic Model
Float moves up and down with the elevation of level in the measuring tube, based on the principle of buoyancy. Permanent magnet steel in the float drives the red and white column roll over 180°by Magnetic Coupling effect. The column turns from white to red when the level rise, conversely, the column turns from red to white. Thus the level indication is realized.
Upper and Lower Limit Switch Output
The alarm switch on the set position of standpipe acts according to the magnetic float moving with the elevation of level. Thus it can realize ON-OFF control or alarm.
Electrical Remote Transmission
Transmitter is mounted on the magnetic level meter. The transmitter consists of sensor and transducer. It moves up and down the magnetic sub measurement measuring element followed by action role within the catheter by the magnetic coupling resistance signal change converts the standard 4 ~ 20mA current signal output, so that the digital display instrument or computer connection, Remote Display.
l Main Technical Parameters
Installation | Side-Mounted | Top-Mounted | ||
Installation Interval | Stainless Steel | 500-5000mm | 500-2500mmm | |
PP | 500-4000mm | |||
Working Pressure | 0.6,1.6,2.5,4.0MPa | 0.6,1.6,2.5,MPa | ||
Medium Density | ≥0.6g/cm3 | ≥0.76g/cm3 | ||
Flange | Stainless Steel | 20-40 (DN20,PN4.0) (GB/T9119-2000) | 200-25 (DN200,PN2.5) (GB/T9119-2000) | |
PP Plastic | 20-10 (DN20,PN1.0) (GB/T9119-2000) | 200-6 (DN200,PN0.6) (GB/T9119-2000) | ||
Body Material | PP Plastic, Stainless Steel | |||
Medium Temperature | -40~80°C 0~150°C 0~300°C (PP Plastic -10~60°C) | |||
Ambient Temperature | -40~70°C | |||
Indication Error | ±10mm | |||
Medium Viscosity | ≤0.07Pa.S | |||
Upper and Lower Limit Switch Output | Sensitivity Control:10mm Output Contact Capacity:AC220V0.5A Transducer:AC220V5A Contact Life:50000 | |||
Electrical Remote Transmission Continuous Display | Accuracy:±1.5% Output Load:4-20mA 0-500Ω Signal Output:DC4-20mA,Two-wire system Explosion-proof: iaⅡCT4 Intrinsically Safe |
Note: 1. Side-Mounted: Stainless Steel: Measuring Range= Installation Space
PP: Indication Range= Installation Space L- 150mm
2. Installation Space (Measuring Range) Size: 500-5000mm (belonging to special orders design if longer than 5000mm)
UHZ series( Upper and Lower Limit Switch )Magnetic Level Gauge